Home > Return Code > Return Code 28 In Mainframe

Return Code 28 In Mainframe

Contents

Attempt has been made to store a record that would create a duplicate key in the indexed or relative file OR a duplicate alternate record key that does not allow duplicates. RESOURCE NOT AVAILABLE' 007500 WHEN '94' DISPLAY 'VSAM - SEQUENTIAL READ AFTER END OF FILE' 007600 DISPLAY 'OR NO CURRENT REC POINTER FOR SEQ' 007700 WHEN '95' DISPLAY 'VSAM - INVALID We appreciate hearing from you. MAXIMUM CONDITION CODE WAS 12 ******************************** Bottom of Data ************************ Cheers Mohan Bezawada Gregory Palgrave Re: vsam i/o return code 28 January 31, 2002 12:53 AM (in response to Bezawada (B.) navigate here

CONDITION CODE = 12 .AXI17 - KWIK-LOAD PROCESSING IS COMPLETED. Either there is not enough space left to make the secondary allocation request, you attempted to increase the size of a data set while processing with SHROPT=4 and This could be on a single volume, or two volumes, but most likely SMS put each primary on a different volume.The analysis that should have been done before the VSAM allocation: Therefore, the file status-key-2 may not always be a numeric value that is easy to display. http://ibmmainframes.com/about15967.html

Vsam Repro Return Code 28

We have a team of individuals that understand the broad range of technologies being used in today's environments. We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms. Indicates a duplicate key condition. StatusKey-1Description by Group 0Successful Completion or non-terminal condition that may be acceptable to continue processing.

  • if yes can you explain? 3 Answers Temenos, What is the COBOL RECORD KEY clause? 2 Answers What does the KEYRANGES parameter in Define Cluster commend do? 1 Answers
  • If you don't check the code when dealing with QSAM files, the system abends your program in case of serious error, and gives you a system completion code.
  • Trying to open a file that does not exist.May need to map the COBOL file name to the physical file name. (Micro Focus, refer to the ASSIGN(EXTERNAL) directive). 37 An OPEN

CONDITION CODE IS 12 0 0IDC0002I IDCAMS PROCESSING COMPLETE. It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. We verified that the production VSAM file created is in same test pool . And also I increased TRACKS for alternate index from (6000 600) to (7000 700) and also increased CONTROLINTERVALSIZE from 4096 to 8192 for cluster creation.

We specialize in the creation and deployment of business applications using new or existing technologies and services. Vsam Error Codes Refer to the section for Status-Key-1 being equal to "0" for additional information based on Status-Key-2. 1End of File, attempting to read beyond the end of the file. These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats. The request cannot be fulfilled by the server To use Google Groups Discussions, please enable JavaScript in your browser settings, and then refresh this page. .

The function delivered in this version is based upon the enhancement requests from a specific group of users. This condition indicates that an attempt has been made to write beyond the externally defined boundaries of a sequential file. 35 An OPEN operation with the I-O, INPUT, or EXTEND phrases The value is placed in the status key before execution of any EXCEPTION/ERROR declarative or INVALID KEY/AT END phrase associated with the request. For Shared Resources, buffer pool is full. 016(10) Record not found. 020(14) Record already held in exclusive control by another requester. 024(18) Record resides on a volume that cannot be mounted.

Vsam Error Codes

This error could also be due to a data set trying to extend beyond 4GB on a system that does not support extended addressability. A good place to start is The SimoTime Home Page via Internet Connect for access to white papers, program examples and product information. Vsam Repro Return Code 28 You can check them in the same way that you check VSAM files. Idc3351i The error may be caused by an invalid key or the sequence of processing for a valid key.

This can be caused by issuing a read after the end-of-file has been reached during sequential processing. 9149 95 Wrong open mode or access mode for REWRITE/ DELETE. 9150 96 Program http://arnoldtechweb.com/return-code/scp-return-code-256.html Books on Vsam Vsam Manuals / Tutorials VSAM error code, VSAM file status, VSAM/QSAM status key, abend codes error code, file status, status key, VSAM open error, QSAM open error, VSAM The job was restarted from the top so it will be 10 hours before it gets to the failing step. "So , in the sense , the production job was recovered For an OPEN or CLOSE statement with the REEL/UNIT phrase the referenced file is a non-reel/unit medium. 08 Attempted to read from a file opened for output. 09 No room in Iec070i 209-220

SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. SMS vs. Refer to the section for Status-Key-1 being equal to "9" for additional information based on Status-Key-2. http://arnoldtechweb.com/return-code/return-code-220.html Explore How to Obtain and Display the File Status after attempting to access a data file or VSAM data set.

The following table lists +---------------+--------------------------------------------------------| | 004 | End of volume - Non-extended addressable. Robert Sample Global moderator Posts: 3156Joined: Sat Dec 19, 2009 8:32 pmLocation: East Dubuque, Illinois Hasthanked: 1 time Beenthanked: 190 times Top Re: Unable to copy a flat file to So here my problem is , when i run the same job JCL (which got failed in production) using the personal datasets in spool , the job completed fine .

If so, how many records?

Other possible causes are: 1. QSAM files (ordinary, sequential, flat files) can be made to return a code to you, if you wish. SORT RETURN CODE = 0 .AXI02 - ALTERNATE INDEX WAS NOT BUILT DUE TO ERRORS. Alternate indexes are incorrectly defined (Key length or position, duplicates or sparse parameters). 2.

In this case, the physical size of the new record is allowed to be smaller than that of the record being replaced. 46 A sequential READ operation has been tried on The ascending key requirements of successive record key values has been violated or the prime record key value has been changed by a COBOL program between successful execution of a READ non-SMS DASD.Just curious if any records loaded to your VSAM file? weblink Robert Sample Global moderator Posts: 3156Joined: Sat Dec 19, 2009 8:32 pmLocation: East Dubuque, Illinois Hasthanked: 1 time Beenthanked: 190 times Top Re: Unable to copy a flat file to

Many vendors take advantage of the x"00' to x'FF' (or 0-255) binary value. Check the current size & extents of the output file, then make it bigger or move to other dasd with enough free space. IDC0005I NUMBER OF RECORDS PROCESSED WAS 5836320 IDC3003I FUNCTION TERMINATED. AIXKEY=(12,10) .AXS06 - UNABLE TO EXECUTE VSAM WRITE.

Therefore, the file status key may not always be a numeric value that is easy to display. Kolusu Back to top sumaBeginnerJoined: 23 Jan 2006Posts: 65Topics: 29 Posted: Wed Apr 01, 2009 4:47 am Post subject: Thaks Kolusu, As part of solution I have changed the TRACKS from Refer to the section for Status-Key-1 being equal to "1" for additional information based on Status-Key-2. 2Invalid Key, an attemprt to access a file failed because the requested key is not Can anyone help me out what it means.. //STEP002 EXEC PGM=IDCAMS //INDD1 DD DSN=JQVEH.TEST.V.D004.VEH.MASTER.VVMOU001.SORT, // DISP=SHR //OUTDD1 DD DSN=JQVEH.TEST.V.D004.VEH.MASTER.VVMOU001.BIT, // DISP=SHR //SYSPRINT DD SYSOUT=* //SYSIN DD * REPRO - INFILE(INDD1) -